Karya
Judul/Title Load variation analysis of heat rate in electricity generation and costs efficiency analysis of 3x330 MW coal-fired power plant: Case study from Indramayu coal-fired power plant, Indonesia
Penulis/Author ACHMAD FAISAL (1); FERDINAND MAYCELLO (2); Ir. Muhammad Akhsin Muflikhun, S.T., MSME., Ph.D (3)
Tanggal/Date 2023
Kata Kunci/Keyword
Abstrak/Abstract . Fuel consumption and the output power of coal-fired power plants with a capacity of 3 × 300 MW, powered by a pulverized coal-fired boiler in Indramayu, Indonesia were analyzed the compared in the present study. Analysis of the plant’s cost efficiency was constructed with indicators in the present study such as operating fuel consumption, power output, nett plant heat rate (NHPR), and cost reduction potency were used to analyze the cost-efficiency. Results show that based on the calculation of the 50%, 75%, 100%, and 100% commissioning load, cost efficiency can be acquired with US$ 26.000. with NPHR of 2.895,55 kCal/kWh, US$ 46.780. with NPHR of 2.781,45 kCal/kWh, US$ 71.580. with NPHR 2.668,62 kCal/kWh, and US$ 86.500. with NPHR 2.463,34 kCal/kWh. Based on the research conducted, reasonable efficiency can be achieved and the value of NPHR can be reduced with the load percentages increased
Level Internasional
Status
Dokumen Karya
No Judul Tipe Dokumen Aksi
1M_ Akhsin M_Prosiding ICST_5_0114161.pdf[PAK] Full Dokumen